Ampower

- Isolation Transformer -​

Product Description

Isolation Transformer are designed to obtain the isolation between incoming power supply and a powered circuit or powered equipment for the security purpose.

Machine or equipment can be isolated from the rest of the electrical installation with the help of the isolation transformer, so power loss can be avoided during installation fault

An isolation transformer can be used to create a star point in grids that do not have such a point, It can be used in sensitive equipment, to provide an isolated neutral ground

Switching of electrical utilities in Industrial & Commercial environment generates spikes & high frequency power line Noises. The spikes can cause the failure of thyristors, Micro-processors, or another active electronic device. The high frequency noises can interfere with Digital-Electronic equipment causing data corruption, erratic behavior, loss of memory etc.

A M Power Isolation Transformer eliminates such noises & attenuates the spikes to negligible values, providing complete protection against such electrical disturbances

Specifications

Neutral Conductor: 100%

Frequency: 50 +/-3 Hz / 60 Hz on request

Regulation: 2–4 % or as required

Impedance: Max. 4 % or as required

Input/Output configuration(single phase): Line–Neutral / Earth

Enclosure Protection Class: IP21 for Air Cooled

Termination Type: Terminal Board / Stud – Bolts / Bus Bar

Efficiency: Better than 97%

Insulation Class / Level: F Class / 155 deg. C & H Class / 180 deg. C

Winding: 99.9% pure Electrolytic grade Copper / Aluminum

Coupling Capacitance: Better than 0.1 pf / other on request

Common mode Noise Attenuation: 80 – 100 dB / better on request

High Voltage Breakdown Test: 2.5 KV for one Minute Between windings and Earth

Galvanic Insulation: Better than 500 Mega-Ohms-DC Isolation @ 2500V

Construction: Double wound, multiple shielding technic, Varnish and vacuum impregnated
Input/Output configuration(three phase): Delta/Star (Dyn11 standard vector Group/other on request)

  • Isolation between a source and equipment ensures the improved safety of the Operator and equipment’s.
  • Reduced Surges and Spikes, High frequency Noise Reduction with special Shielding technique.
  • High performance or efficiency.
  • Reduced coupling capacitance
  • It can block interference caused by ground loops
  • Better Power Quality
  • Block transmission of the DC component
  • Lower leakage current and Output Impedance.
  • Coil design is optimized for low eddy current loss and high harmonic current carrying capacity
  • Cores designed for reduced flux densities to compensate for harmonic voltage distortion.
  • 100 % Neutral current carrying capacity
  • 100 % Neutral current carrying capacity
  • Quiet operation
  • Analog / Digital Metering for Input and Output Voltages
  • Output On Indication LED/Lamps
  • Digital Earth Leakage Meter for sophistication machines and Instruments
  • Input Circuit breaker
  • Multiple Tapping at Input and Output

Specifications

TypeRatingsInput VoltageOutput Voltage
1 Phase1 – 50 KVA220 / 230 / 240220 / 230 / 240
220 / 230 / 240100 / 110 / 120
Unbalance
3 Phase
Air Cooled
5 – 150 KVA380 / 400 / 415 / 440380 / 400 / 415 / 460
380 / 400 / 415 / 440200 / 220
380 / 400 / 415 / 440200 & 220
Unbalance
3 Phase
Air Cooled
50 – 1000 KVA380 / 400 / 415 / 440380 / 400 / 415 / 460
380 / 400 / 415 / 440200 / 220
380 / 400 / 415 / 440200 & 220
×
×